3-18-3, Pragathi Nagar, Ramanthapur,
Hyderabad – 500013. A.P. India.
Off.: 27038560/1929
E-mail: apmotronix@gmail.com

 
Solenoid Series Rotary

Overview

Solenoids are classified based on the type of Voltage (AC or DC), Action (Linear or Rotational) and Electrical Duty Cycle (EDC). Solenoid consists of a coil wound on a bobbin encapsulated in a frame of suitable size. The bobbin has a through hole in which the plunger operates. When the coil is energized magneto motive force develops, forcing the plunger to minimize the path of magnetic reluctance. In Rotary Solenoid this motion of the plunger is rotational. The stroke angle and torque developed by the rotation of the plunger is intelligently used to perform predetermined work. These find applications in machineries like textile, pharmaceutical, security, office, and robotics.

 
Series Code

 
Specification



MODEL SOR-CU- MECHANICAL DIMENSIONS (FOR ALL ROTATION ANGLES)
D1 D2 D3 D4 D5 PCD L1 L2 L3 L4 L5 L6 L7*
025 3.0 25.0 M3 11.4 23.2 18.0 15.0 25.0 55.0 5.5 100.0 3.2 3.0
035 4.0 35.0 M3 14.6 33.4 25.0 10.0 27.5 47.5 7.0 100.0 4.5 3.5
050 6.0 50.0 M4 20.8 48.0 35.0 20.0 38.0 78.0 8.5 150.0 4.7 5.0
060 8.0 60.0 M4 24.0 57.5 40.0 18.0 42.0 78.0 10.0 150.0 6.0 6.0
075 10.0 75.0 M5 29.5 72.0 50.0 25.0 53.0 103.0 12.5 200.0 8.5 8.0
100 12.0 100.0 M6 32.0 96.0 70.0 25.0 68.0 118.0 16.0 260.0 10.0 9.0


L7*:Over-length mounting screws will damage the coil.

 
Data Sheet
SOR-CU-025
MODEL SOR-CU-025- Voltage (V) 24 205
EDC (%) 100 48 27 14 4.4 100 50 18 8 5
Current (A) 0.16 0.32 0.55 1.02 3.04 0.01 0.03 0.09 0.19 0.30
Torque (Kg-cm) 250 Mi 0.03 0.06 0.10 0.15 0.28 0.02 0.05 0.11 0.19 0.25
Mf 0.05 0.01 0.14 0.18 0.27 0.04 0.09 0.15 0.22 0.26
350 Mi 0.02 0.05 0.08 0.12 0.25 0.02 0.04 0.09 0.16 0.22
Mf 0.04 0.09 0.12 0.16 0.25 0.03 0.08 0.13 0.19 0.24
450 Mi 0.01 0.04 0.06 0.10 0.21 0.01 0.03 0.07 0.13 0.19
Mf 0.04 0.08 0.11 0.15 0.22 0.03 0.07 0.12 0.17 0.21
650 Mi 0.01 0.03 0.05 0.08 0.18 0.008 0.02 0.05 0.11 0.16
Mf 0.04 0.07 0.10 0.13 0.19 0.03 0.06 0.10 0.15 0.17
950 Mi 0.006 0.01 0.03 0.05 0.13 0.004 0.01 0.03 0.07 0.11
Mf 0.003 0.06 0.09 0.11 0.13 0.02 0.06 0.09 0.12 0.13

Mi is torque at start of angular stroke. Mf is torque at 50 before end of stroke.

SOR-CU-035
MODEL SOR-CU-035- Voltage (V) 24 205
EDC (%) 100 38 24 15 4.4 100 39 22 14 5
Current (A) 0.25 0.58 0.87 1.36 4.28 0.03 0.07 0.11 0.17 0.40
Torque (Kg-cm) 250 Mi 0.11 0.24 0.33 0.42 0.69 0.10 0.21 0.32 0.41 0.59
Mf 0.21 0.35 0.41 0.48 0.63 0.20 0.32 0.04 0.47 0.59
350 Mi 0.09 0.22 0.30 0.37 0.64 0.08 0.20 0.26 0.36 0.53
Mf 0.18 0.33 0.38 0.43 0.49 0.17 0.28 0.36 0.41 0.48
450 Mi 0.06 0.18 0.26 0.34 0.56 0.05 0.15 0.23 0.31 0.47
Mf 0.16 0.29 0.34 0.38 0.43 0.14 0.26 0.32 0.38 0.42
650 Mi 0.04 0.11 0.15 0.22 0.44 0.03 0.08 0.14 0.20 0.35
Mf 0.13 0.24 0.28 0.33 0.37 0.12 0.22 0.26 0.32 0.36
950 Mi 0.01 0.05 0.09 0.13 0.25 0.01 0.04 0.08 0.12 0.21
Mf 0.12 0.21 0.24 0.25 0.25 0.10 0.19 0.23 0.24 0.25

SOR-CU-050
MODEL SOR-CU-050- Voltage (V) 24 205
EDC (%) 100 44 21 13 5 100 35 22 13 5
Current (A) 0.42 0.87 1.74 2.76 6.49 0.04 0.12 0.19 0.32 0.84
Torque (Kg-cm) 250 Mi 0.68 1.14 1.60 1.85 2.35 0.58 1.15 1.45 1.75 2.30
Mf 1.15 1.53 1.90 2.13 2.60 1.05 1.54 1.75 2.10 2.5
350 Mi 0.52 0.94 1.35 1.60 2.20 0.44 0.95 1.22 1.52 2.10
Mf 1.02 1.35 1.60 1.75 2.00 0.94 1.36 1.52 1.70 1.95
450 Mi 0.36 0.68 1.10 1.38 1.88 0.31 0.69 0.96 1.25 1.80
Mf 0.93 1.25 1.45 1.60 1.80 0.86 1.25 1.40 1.55 1.77
650 Mi 0.22 0.44 0.81 1.03 1.55 0.19 0.45 0.67 0.98 1.45
Mf 0.86 1.15 1.35 1.43 1.50 0.81 1.16 1.28 1.40 1.50
950 Mi 0.08 0.22 0.41 0.56 0.98 0.06 0.22 0.33 0.51 0.91
Mf 0.72 0.89 0.98 0.98 0.92 0.66 0.90 0.96 0.98 0.92

SOR-CU-060
MODEL SOR-CU-060- Voltage (V) 24 205
EDC (%) 100 44 27 17 5 100 34 20 12 5
Current (A) 0.56 1.13 1.75 2.70 8.60 0.14 0.16 0.28 0.43 0.98
Torque (Kg-cm) 250 Mi 1.20 2.10 2.45 2.85 4.00 1.10 2.15 2.55 2.95 3.80
Mf 2.50 3.10 3.45 3.80 4.45 2.30 3.10 3.50 3.80 4.40
350 Mi 0.90 1.55 1.90 2.30 3.30 0.75 1.60 2.10 2.40 3.10
Mf 2.20 2.70 3.00 3.20 3.60 2.00 2.70 3.00 3.20 3.55
450 Mi 0.60 1.15 1.50 1.90 2.85 0.50 1.20 1.60 2.00 2.70
Mf 2.00 2.50 2.70 2.90 3.05 1.90 2.50 2.70 2.90 3.05
650 Mi 0.32 0.74 1.05 1.45 2.35 0.26 0.75 1.10 1.50 2.20
Mf 1.95 2.30 2.40 2.50 2.60 1.75 2.30 2.40 2.50 2.60
950 Mi 0.13 0.33 0.47 0.70 1.32 0.11 0.32 0.52 0.76 1.20
Mf 1.50 1.70 1.70 1.66 1.42 1.42 1.70 1.70 1.66 1.40


SOR-CU-075:
MODEL SOR-CU-075- Voltage (V) 24 205
EDC (%) 100 37 23 14 5 100 36 23 14 5
Current (A) 0.82 2.10 3.20 4.90 12.60 0.10 0.23 0.36 0.55 1.40
Torque (Kg-cm) 250 Mi 3.55 5.50 6.50 7.20 8.90 3.20 5.10 6.00 7.00 8.60
Mf 4.80 6.40 7.30 8.00 8.90 4.70 6.10 7.00 7.50 8.80
350 Mi 2.80 4.80 5.70 6.50 8.10 2.60 4.40 5.10 6.20 8.00
Mf 4.30 5.60 6.00 6.30 6.70 4.15 5.30 5.80 6.20 6.60
450 Mi 2.30 4.10 5.00 5.80 7.50 2.10 3.70 4.60 5.40 7.30
Mf 4.00 5.00 5.40 5.60 5.80 3.80 4.90 5.20 5.50 5.80
650 Mi 1.35 2.60 3.40 4.20 6.00 1.20 2.40 3.10 3.80 5.70
Mf 3.40 4.20 4.40 4.40 4.20 3.30 4.00 4.50 4.40 4.20
950 Mi 0.62 1.50 2.15 2.70 4.20 0.56 1.30 1.85 2.50 4.10
Mf 2.60 3.00 3.00 3.00 2.50 2.50 2.95 3.00 3.00 2.50


SOR-CU-100:

MODEL SOR-CU-100- Voltage (V) 24 205
Current (A) 1.35 2.70 3.40 5.30 8.30 0.16 0.38 0.76 1.19 2.42
EDC (%) 100 46 36 22 14 100 37 18 11 5
TORQUE (Kg-cm) 250 Mi 8.80 12.5 13.8 16.0 17.5 7.90 12.5 16.0 17.7 20.4
Mf 12.5 15.5 16.3 18.2 19.5 11.7 15.2 18.2 19.8 22.0
350 Mi 7.1 10.4 11.6 13.7 15.4 6.10 10.40 13.70 15.70 18.40
Mf 11.20 13.80 14.70 16.00 16.80 10.60 13.80 16.00 16.80 17.00
450 Mi 5.30 8.60 9.80 11.90 13.70 4.60 8.60 11.90 14.00 16.70
Mf 10.80 13.00 13.60 14.50 15.00 10.20 13.00 14.50 15.00 15.00
650 Mi 3.10 5.20 6.20 8.30 10.00 2.60 5.20 8.30 10.50 12.50
Mf 9.70 11.20 11.70 12.20 12.30 9.10 11.20 12.20 12.30 11.50
950 Mi 1.30 2.20 2.70 3.70 4.60 1.10 2.20 3.70 4.80 6.30
Mf 7.20 8.30 8.50 8.70 8.60 6.80 8.20 8.70 8.50 7.80

 

 
Ordering data

Apart from the series code, clearly indicate in your order the following:

Operating Voltage : Value and if AC or DC.
Duty Cycle : In Percentage (or the Solenoid ON & OFF Times).    
Torque : Kg-cm
Special Requirement : Feedback micro switch (for end of stroke angle indication), special shaft lengths & profiles.

 

 
HOME   |   ABOUT US   |   PRODUCTS   |   PRODUCT SPARES   |   INDUSTRY APPLICATIONS   |   INDUSTRY JOB SERVICES  |   REACH US